General specifications | |
---|---|
Sensing range | 20 ... 60 mm , optimal distance: 45 mm |
Transducer frequency | 255 kHz |
Indicators/operating means | |
LED green | indication: single sheet detected |
LED yellow | Indication: No sheet detected (Air) |
LED red | indication: double sheet detected |
Electrical specifications | |
Operating voltage | 18 ... 30 V DC , ripple10%SS |
No-load supply current | < 50 mA |
Input | |
Input type | Function input 0-level: -UB ... -UB + 1V 1-level: +UB - 1 V ... +UB |
Pulse length | ? 100 ms |
Impedance | ? 4 k? |
Output | |
Output type | 3 switch outputs NPN, NC |
Rated operating current | 3 x 100 mA , short-circuit/overload protected |
Voltage drop | ? 3 V |
Switch-on delay | approx. 15 ms (shorter response time on request) |
Switch-off delay | approx. 15 ms (shorter response time on request) |
Pulse extension | min. 120 ms programmable |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | 0 ... 60 °C (32 ... 140 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Connection type | cable PVC , 2 m |
Core cross-section | 0.14 mm2 |
Degree of protection | IP67 |
Material | |
Mass | 135 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |